c0mm0.com — the continuously verified register of European data

Register record·API·DEVERIFIED · checked 10h ago
L

Hamburg Airport Noise Protection ZoneLärmschutzbereich Flughafen Hamburg

Lärmschutzbereich Flughafen HamburgHamburg Airport Noise Protection Zone

Published by LGV Hamburg

APIExecutable4/7Query nowOpen workbenchSubscribe🇩🇪Germany

This WFS service provides geodata on noise protection zones around Hamburg Airport, published by LGV Hamburg (Landesbetrieb Geoinformation und Vermessung). It supports noise action planning under the Environmental Noise Directive for the Hamburg metropolitan area, monitoring compliance with night-flight restrictions and the handling of exemption permits, management of aircraft noise complaints, and calculation of noise protection zones in accordance with the Aircraft Noise Act of June 2007. Data layers include night and daytime protection zones and their respective area boundaries.”Lärmaktionsplanung nach Umgebungslärmrichtlinie für den Ballungsraum Hamburg - Überwachung der Einhaltung von Nachtflugbeschränkungen und Erteilung von Ausnahmegenehmigungen; - Fluglärmbeschwerdemanagement - Berechnung der Fluglärmschutzzonen nach dem Fluglärmgesetz von Juni 2007

40
fair

Weighted across five axes. Tap a ring for what it measures.

Data schema (29 fields)

Click a field to see example values.

FieldTypeDescription
bezstringDesignation or label of the noise protection zone.Designation or label of the noise protection zone.
markstringMarker symbol used for the zone or contour point.Marker symbol used for the zone or contour point.
idstringIdentifier of the data layer or contour type.Identifier of the data layer or contour type.
lwtdecimalNoise level value for the daytime period.Noise level value for the daytime period.
lwedecimalNoise level value for the evening period.Noise level value for the evening period.
lwndecimalNoise level value for the night period.Noise level value for the night period.
lwstdecimalReference noise level value for daytime.Reference noise level value for daytime.
lwsedecimalReference noise level value for evening.Reference noise level value for evening.
lwsndecimalReference noise level value for night.Reference noise level value for night.
lwtypstringType or category of the noise level indicator.Type or category of the noise level indicator.
lw_liLw listringLabel or line identifier associated with the noise level.Label or line identifier associated with the noise level.
norm_aNorm adecimalNormalisation factor A applied in the noise calculation.Normalisation factor A applied in the noise calculation.
ktdecimalCorrection factor applied to the daytime noise level.Correction factor applied to the daytime noise level.
kedecimalCorrection factor applied to the evening noise level.Correction factor applied to the evening noise level.
kndecimalCorrection factor applied to the night noise level.Correction factor applied to the night noise level.
rwstringEasting coordinate value (Rechtswert) of the location.Easting coordinate value (Rechtswert) of the location.
flaechedecimalArea of the noise protection zone.Area of the noise protection zone.
dmpstringDamping or attenuation parameter used in the calculation.Damping or attenuation parameter used in the calculation.
teinwtdecimalNumber of residents affected during the daytime period.Number of residents affected during the daytime period.
teinwrdecimalNumber of residents affected during the rest/quiet period.Number of residents affected during the rest/quiet period.
teinwndecimalNumber of residents affected during the night period.Number of residents affected during the night period.
k0decimalBaseline correction constant used in the noise calculation.Baseline correction constant used in the noise calculation.
freqFrequencyintegerFrequency band, in hertz, used for the noise calculation.Frequency band, in hertz, used for the noise calculation.
richtwstringApplicable guideline or reference noise value.Applicable guideline or reference noise value.
pq_anztPq anztdecimalCount of measurement points used for daytime calculation.Count of measurement points used for daytime calculation.
pq_anzePq anzedecimalCount of measurement points used for evening calculation.Count of measurement points used for evening calculation.
pq_anznPq anzndecimalCount of measurement points used for night calculation.Count of measurement points used for night calculation.
geomgeometryGeometric shape representing the noise protection zone.Geometric shape representing the noise protection zone.
dbintegerNoise level value expressed in decibels.Noise level value expressed in decibels.

Schema captured from wfs 3 days ago.

Query the data

Pick columns and a sort, then fetch a live preview straight from the source. Choose an API-filterable column (marked ▾) under “Where” to pick from its list of values.

=

Sample data (1 record)

Record 1id: CNA_FLG_CONTOUR · k0: 0
{
  "id": "CNA_FLG_CONTOUR",
  "k0": 0,
  "ke": 0,
  "kn": 0,
  "kt": 0,
  "rw": " ",
  "bez": "TSZ2",
  "dmp": " ",
  "lwe": 0,
  "lwn": 0,
  "lwt": 0,
  "freq": 500,
  "lwse": 0,
  "lwsn": 0,
  "lwst": 0,
  "mark": "+",
  "lw_li": " ",
  "lwtyp": "Lw\"",
  "norm_a": 0,
  "richtw": "(kein",
  "teinwn": 0,
  "teinwr": 0,
  "teinwt": 0,
  "flaeche": 0,
  "pq_anze": 0,
  "pq_anzn": 0,
  "pq_anzt": 0
}

Live sample captured at profiling time — values may have changed upstream.

Verification Status

Using the API

Query examples

curl -s 'https://geodienste.hamburg.de/HH_WFS_Fluglaermschutzzonen?service=WFS&version=2.0.0&request=GetCapabilities' -H 'Accept: application/json'

List the feature types (layers) and supported operations.

Dataset

Volume & freshness

Datasets
5
on this portal

License

No license declared upstream.

○ Documentation○ Data dictionary○ Versioning

Machine-readable & source

Lärmschutzbereich Flughafen Hamburg — live verification badge

Embed this badge in a README or wiki — it always shows the latest verification state and quality tier.