c0mm0.com — the continuously verified register of European data

Register record·API·FRUNVERIFIED
P

PLN_Analyse-SEDIMENTS_2023

APIQuery nowOpen workbench🇫🇷France

Analyse sediments PLN 2023

0
poor

Weighted across five axes. Tap a ring for what it measures.

Data schema (32 fields)

Filterable via the API (32)
code_stationnom_stationpoint_de_prelevementprofondeurreference_analysedate_et_heure_de_prelevementdate_et_heure_de_reception_de_l_echantillondate_et_heure_de_l_analysecode_reseaucode_preleveurcode_laboratoirecode_parametrecode_supportcode_fractionlimite_de_detectionlimite_de_quantificationcode_remarqueresultat_analysecode_unite_sandrelibelle_court_unite_sandrenom_parametre_sandrecode_methode_analyse_sandrecode_methode_extraction_sandreaccreditation_cofracincertitude_analytiquetype_d_incertitude_analytiquerendement_d_extractioncommentairecode_demandecode_prelevementcode_zone_verticale_prospecteecode_maitre_d_ouvrage

Click a field to see example values.

FillFieldTypeDescription
100%code_stationFilterable via the APICode stationtext
0%nom_stationFilterable via the APINom stationtext
100%point_de_prelevementFilterable via the APIPoint de prélèvementtext
0%profondeurFilterable via the APItext
100%reference_analyseFilterable via the APIRéférence analysetext
100%date_et_heure_de_prelevementFilterable via the APIDate et heure de prélèvementtext
100%date_et_heure_de_reception_de_l_echantillonFilterable via the APIDate et heure de réception de l'échantillontext
100%date_et_heure_de_l_analyseFilterable via the APIDate et heure de l analysetext
0%code_reseauFilterable via the APICode réseautext
0%code_preleveurFilterable via the APICode préleveurtext
100%code_laboratoireFilterable via the APICode laboratoiretext
100%code_parametreFilterable via the APICode paramètretext
100%code_supportFilterable via the APICode supporttext
100%code_fractionFilterable via the APICode fractiontext
88%limite_de_detectionFilterable via the APILimite de détectiontext
90%limite_de_quantificationFilterable via the APILimite de quantificationtext
100%code_remarqueFilterable via the APICode remarquetext
99.9%resultat_analyseFilterable via the APIRésultat analysetext
98%code_unite_sandreFilterable via the APICode unité SANDREtext
98%libelle_court_unite_sandreFilterable via the APILibellé court unité SANDREtext
100%nom_parametre_sandreFilterable via the APINom paramètre SANDREtext
96%code_methode_analyse_sandreFilterable via the APICode méthode analyse SANDREtext
0%code_methode_extraction_sandreFilterable via the APICode méthode extraction SANDREtext
100%accreditation_cofracFilterable via the APIAccréditation COFRACtext
76%incertitude_analytiqueFilterable via the APIIncertitude analytiquetext
100%type_d_incertitude_analytiqueFilterable via the APIType d incertitude analytiquetext
100%rendement_d_extractionFilterable via the APIRendement d extractiontext
100%commentaireFilterable via the APItext
0%code_demandeFilterable via the APICode demandetext
0%code_prelevementFilterable via the APICode prélèvementtext
0%code_zone_verticale_prospecteeFilterable via the APICode zone verticale prospecteetext
0%code_maitre_d_ouvrageFilterable via the APICode maitre d ouvragetext

Schema captured from opendatasoft 2 hours ago.

Query the data

Pick columns and a sort, then fetch a live preview straight from the source. Choose an API-filterable column (marked ▾) under “Where” to pick from its list of values.

=

Sample data (5 records)

Record 1profondeur: — · code_reseau: —
{
  "profondeur": null,
  "code_reseau": null,
  "commentaire": "GC/MS/MS après extr à chaud sous pression / Méthode interne M-ST284",
  "nom_station": null,
  "code_demande": null,
  "code_station": "PLN-SED-39",
  "code_support": "00",
  "code_fraction": "144",
  "code_remarque": "10",
  "code_parametre": "1476",
  "code_preleveur": null,
  "code_laboratoire": "41054531300042",
  "code_prelevement": null,
  "resultat_analyse": "10.00",
  "code_unite_sandre": "132",
  "reference_analyse": "LSE2306-10141",
  "limite_de_detection": "3.00",
  "accreditation_cofrac": "1",
  "nom_parametre_sandre": "Chrysène",
  "point_de_prelevement": "PLN-SED-39/2",
  "code_maitre_d_ouvrage": null,
  "incertitude_analytique": "45",
  "rendement_d_extraction": "100",
  "limite_de_quantification": "10.00",
  "date_et_heure_de_l_analyse": "20/07/2023 22:01:52",
  "libelle_court_unite_sandre": "µg/(kg MS)",
  "code_methode_analyse_sandre": "405",
  "date_et_heure_de_prelevement": "04/07/2023 00:00:00",
  "type_d_incertitude_analytique": "2",
  "code_methode_extraction_sandre": null,
  "code_zone_verticale_prospectee": null,
  "date_et_heure_de_reception_de_l_echantillon": "06/07/2023 05:09:00"
}
Record 2profondeur: — · code_reseau: —
{
  "profondeur": null,
  "code_reseau": null,
  "commentaire": "GC/MS/MS après extr. hexane / XP T90-250",
  "nom_station": null,
  "code_demande": null,
  "code_station": "PLN-SED-34",
  "code_support": "00",
  "code_fraction": "144",
  "code_remarque": "10",
  "code_parametre": "2879",
  "code_preleveur": null,
  "code_laboratoire": "41054531300042",
  "code_prelevement": null,
  "resultat_analyse": "4.9",
  "code_unite_sandre": "132",
  "reference_analyse": "LSE2306-10139",
  "limite_de_detection": "1.7",
  "accreditation_cofrac": "2",
  "nom_parametre_sandre": "Tributtin+",
  "point_de_prelevement": "PLN-SED-34/2",
  "code_maitre_d_ouvrage": null,
  "incertitude_analytique": "60",
  "rendement_d_extraction": "100",
  "limite_de_quantification": "5.0",
  "date_et_heure_de_l_analyse": "24/07/2023 06:12:00",
  "libelle_court_unite_sandre": "µg/(kg MS)",
  "code_methode_analyse_sandre": "405",
  "date_et_heure_de_prelevement": "04/07/2023 00:00:00",
  "type_d_incertitude_analytique": "2",
  "code_methode_extraction_sandre": null,
  "code_zone_verticale_prospectee": null,
  "date_et_heure_de_reception_de_l_echantillon": "06/07/2023 05:09:00"
}
Record 3profondeur: — · code_reseau: —
{
  "profondeur": null,
  "code_reseau": null,
  "commentaire": "GC/MS/MS après extr à chaud sous pression / Méthode interne M-ST284",
  "nom_station": null,
  "code_demande": null,
  "code_station": "PLN-SED-20",
  "code_support": "00",
  "code_fraction": "144",
  "code_remarque": "1",
  "code_parametre": "1117",
  "code_preleveur": null,
  "code_laboratoire": "41054531300042",
  "code_prelevement": null,
  "resultat_analyse": "21.90",
  "code_unite_sandre": "132",
  "reference_analyse": "LSE2306-10132",
  "limite_de_detection": "3.00",
  "accreditation_cofrac": "1",
  "nom_parametre_sandre": "Benzo(k)fl",
  "point_de_prelevement": "PLN-SED-20/2",
  "code_maitre_d_ouvrage": null,
  "incertitude_analytique": "45",
  "rendement_d_extraction": "100",
  "limite_de_quantification": "10.00",
  "date_et_heure_de_l_analyse": "21/07/2023 15:59:01",
  "libelle_court_unite_sandre": "µg/(kg MS)",
  "code_methode_analyse_sandre": "405",
  "date_et_heure_de_prelevement": "04/07/2023 00:00:00",
  "type_d_incertitude_analytique": "2",
  "code_methode_extraction_sandre": null,
  "code_zone_verticale_prospectee": null,
  "date_et_heure_de_reception_de_l_echantillon": "06/07/2023 05:09:00"
}
Record 4profondeur: — · code_reseau: —
{
  "profondeur": null,
  "code_reseau": null,
  "commentaire": "GC/MS/MS après extraction à chaud sous pression / Méthodeinterne M_ST284",
  "nom_station": null,
  "code_demande": null,
  "code_station": "PLN-SED-39",
  "code_support": "00",
  "code_fraction": "144",
  "code_remarque": "10",
  "code_parametre": "1246",
  "code_preleveur": null,
  "code_laboratoire": "41054531300042",
  "code_prelevement": null,
  "resultat_analyse": "1.00",
  "code_unite_sandre": "132",
  "reference_analyse": "LSE2306-10141",
  "limite_de_detection": "0.30",
  "accreditation_cofrac": "2",
  "nom_parametre_sandre": "PCB 180",
  "point_de_prelevement": "PLN-SED-39/2",
  "code_maitre_d_ouvrage": null,
  "incertitude_analytique": "45",
  "rendement_d_extraction": "100",
  "limite_de_quantification": "1.00",
  "date_et_heure_de_l_analyse": "20/07/2023 22:01:52",
  "libelle_court_unite_sandre": "µg/(kg MS)",
  "code_methode_analyse_sandre": "405",
  "date_et_heure_de_prelevement": "04/07/2023 00:00:00",
  "type_d_incertitude_analytique": "2",
  "code_methode_extraction_sandre": null,
  "code_zone_verticale_prospectee": null,
  "date_et_heure_de_reception_de_l_echantillon": "06/07/2023 05:09:00"
}
Record 5profondeur: — · code_reseau: —
{
  "profondeur": null,
  "code_reseau": null,
  "commentaire": "Combustion sèche / NF EN 15936 méth.B",
  "nom_station": null,
  "code_demande": null,
  "code_station": "PLN-SED-45",
  "code_support": "00",
  "code_fraction": "144",
  "code_remarque": "1",
  "code_parametre": "1841",
  "code_preleveur": null,
  "code_laboratoire": "41054531300042",
  "code_prelevement": null,
  "resultat_analyse": "13000.0",
  "code_unite_sandre": "160",
  "reference_analyse": "LSE2306-10116",
  "limite_de_detection": "300.0",
  "accreditation_cofrac": "1",
  "nom_parametre_sandre": "C Orga",
  "point_de_prelevement": "PLN-SED-45/2",
  "code_maitre_d_ouvrage": null,
  "incertitude_analytique": "20",
  "rendement_d_extraction": "100",
  "limite_de_quantification": "1000.0",
  "date_et_heure_de_l_analyse": "07/07/2023 14:04:23",
  "libelle_court_unite_sandre": "mg/(kg MS)",
  "code_methode_analyse_sandre": "3",
  "date_et_heure_de_prelevement": "06/06/2023 12:00:00",
  "type_d_incertitude_analytique": "2",
  "code_methode_extraction_sandre": null,
  "code_zone_verticale_prospectee": null,
  "date_et_heure_de_reception_de_l_echantillon": "09/06/2023 11:01:00"
}

Live sample captured at profiling time — values may have changed upstream.

Using the API

Configuration

Base URL
https://data.laregion.fr/api/explore/v2.1/catalog/datasets/pln_analyse-sediments_2023

License

  • Redistributable
  • Attribution required

Query examples

curl -s 'https://data.laregion.fr/api/explore/v2.1/catalog/datasets/pln_analyse-sediments_2023/records?limit=20' -H 'Accept: application/json'

First 20 records of the dataset as JSON.

Uses the Opendatasoft Explore v2.1 syntax — supports select, where, group_by and order_by.

Full API documentation ↗

Rate limits

5 000 req/day
per ipmeasured
observed 2 hours ago

Dataset

Volume & freshness

Records
1.6k
1550
Last upstream update
2 years ago
2024-11-29

License

No license declared upstream.

Documentation Data dictionary Versioning

Source: opendatasoft

Machine-readable & source

PLN_Analyse-SEDIMENTS_2023 — live verification badge

Embed this badge in a README or wiki — it always shows the latest verification state and quality tier.